WATER SAMPLING DATA

The Village is required per IEPA regulations to ensure that the water going to distribution meets all IEPA safe drinking water standards. Various tests are conducted by the Village and by a third party laboratory, Suburban Labs, Inc.

Water Plant Daily Sampling

Currently, plant effluent sampling of finished water is performed three times daily. The following water parameters are sampled:

  1. Total Hardness
  2. Calcium Hardness
  3. Alkalinity
  4. Iron
  5. pH
  6. Turbidity
  7. Fluoride
  8. TDS
  9. Total chlorine
  10. Free chlorine

The Village also conducts regular bacteria (BacT) and chlorine residual samples at various locations within the Village. Details regarding those samples and sampling locations can be found on the IEPA's Water Watch Website

 


2015 CCR

2016 CCR

2017 CCR

2018 CCR

2019 CCR

2020 CCR

2021 CCR

2022 CCR


   

Contacting the Village

If residents are experiencing issues with the taste or quality of the water at their home, they are encouraged to contact the Water Division at 708-246-1800 x 214. Plant operators can follow up regarding various issues and, if needed, collect a water sample for further analysis.

IEPA Testing

The following data is required to be submitted to the IEPA on the listed timelines below. All sample data submitted to the IEPA is conducted by a third party, independent lab. Detailed information regarding the Village's IEPA testing and test results can be found on the IEPA's website at the Illinois Drinking Water Watch


Per the Safe Water Drinking Act the Village is required to produce an annual report known as the Consumer Confidence Report (CCR). A CCR is an annual water quality report delivered by community water systems to their customers. The CCR includes information on source water, the levels of detected contaminants, compliance with drinking water rules, and some educational information. The reports are due to customers by July 1st of each year, and digital copies can be found below.

 

IEPA monitoring Schedules

Programs
# of Samples
Freq.
Coliform (TCR)
15
Monthly



Distribution



Lead/Copper
30
Annually
Stage 2 DBPR
2
Annually



Generic Finished Sampling Station


Coliform, Total
1
Monthly



Treatment Plant


Comb. Radium
1
Annually
Gross Alpha
1
Every 3 Years
IOC
1
Every 3 Years
Nitrate
1
Annually
Nitrite
1
Every 3 Years
SOC
2
Every 3 Years
Vinyl Choride
1
Every 3 Years
VOC
1
Every 3 Years



Well #1


E. Coli
1
Monthly
IOC
1
Every 3 Years
Nitrate
1
Every 3 Years
Nitrite
1
Every 3 Years
RAD WO U
1
Every 3 Years
SOC W
1
Every 3 Years
Vinyl Chloride
1
Every 3 Years
VOC
1
Every 3 Years



Well #3


E. Coli
1
Monthly


The complete document can be found at the following link: Western Springs Monitoring Schedule.